Inductively Coupled Plasma Mass SpectrometryFullSizeRender 22 1 1547634928 18034

The Agilent 7800 ICP-MS combines proven, robust hardware, auto-optimization tools, and Pre-set Methods to simplify routine analysis. With high matrix tolerance, wide dynamic range, and effective control of polyatomic interferences, the hardware takes the uncertainty out of analyzing complex or variable sample matrices.

  • Fast track your routine metals analysis – ICP-MS MassHunter software includes Pre-Set Methods that can be simply loaded and run with predefined setting, from plasma conditions to analyte integration time and internal standards. For new methods, the Method Wizards builds the method based on sample type and application. Learn more about our drinking water, environmental waste and elemental impurities in pharmaceutical product solutions.
  • Reduce sample preparation – Unique High Matrix Introduction (HMI) technology, standard on the 7800 ICP-MS, lets you analyze samples containing up to 3% total dissolved solids (TDS) without dilution, reducing sample preparation and saving time.  
  • Minimize signal suppression – HMI reduces signal suppression, so high matrix samples can be measured accurately without requiring matrix matched calibration standards. 
  • Ensure accurate data with effective interference removal – Helium (He) collision mode simplifies method development and routine operation by removing polyatomic ion interferences under a single consistent set of conditions. He mode avoids the need for matrix or analyte-specific reaction cell conditions.  
  • Analyze major and trace analytes in a single run – The wide dynamic range orthogonal detector system (ODS)  enables direct analysis of major elements (100s or 1000s of ppm) and trace level analytes (single or sub-ppt) in a single run. The high upper concentration limit reduces sample reruns caused by overrange results. 
  • Maximize throughput and productivity – The optional Integrated Sample Introduction System (ISIS 3) and the SPS 4 Autosampler lower your cost per analysis without compromising data quality

Instrument hardware

Sample Introduction

Nebulizer:
 

Spray Chamber:              

 

 

 
 
Concentric nebulizer with low sample flow
rate as standard (~0.2 mL/min)
 
Quartz, low-volume, Scott-type double-pass spray chamber (Controlled temperature range: -5 °C to +20 °C (with instrument cooling water at 15–30 °C)                                                                           
Peristaltic Pump                          10-roller peristaltic pump

High Matrix Introduction

Agilent’s unique, patented HMI aerosol dilution technology, standard on
the 7800, extends the total dissolved solids (TDS) range to percent level, while eliminating the added costs, time and potential errors of conventional liquid dilution.

 Plasma  

RF generator

High power-transfer efficiency and maintenance-free solid state digital drive 27 MHz RF
generator with variable-frequency impedance matching.

RF power range: 500 W to 1600 W

Torch

Easy-mount, one-piece quartz torch with 2.5 mm
internal diameter injector

Torch position

Stepper-motor controlled in three axes (horizontal, vertical and sampling depth) in 0.1 mm
steps. The torch is automatically realigned with the interface following maintenance.

  • Horizontal and vertical position range: ±2 mm
  • Sampling depth: 3 to 28 mm
ShieldTorch system

 

Controls plasma potential and ion energy - essential to achieve high performance He mode.

 

Robust pre-set plasma conditions

 

Signal suppression for high ionization potential elements such as Be, Zn, As and Cd in 10 vol% HNO3 matrix is typically less than 10% (Plasma mode: General Purpose).

 

Interface  
Sampling cone

 

1 mm diameter orifice, Ni-tipped or Pt-tipped (option) with Cu base

 

Skimmer cone

 

0.4 mm diameter orifice, Ni or Pt-tipped

 

Ion Lens  
Extraction lens

 


Focuses the ions as they enter the intermediate vacuum stage, minimizing space charge
effects and reducing mass bias.

 

Off-axis Omega lens

This double deflection lens protects the cell and high vacuum region from contamination, by rejecting neutral species from the ion beam. This contributes to the minimal mass bias and
low background noise.

 

Octopole Reaction System The 7800 ICP-MS incorporates a new, 4th generation cell , which provides fast cell gas switching
and the most effective interference removal using kinetic energy discrimination (KED) in He mode.
Mass Analyzer

 

 

Quadrupole mass spectrometer

 

Mass range: 2 - 260 amu
• Abundance Sensitivity (at Cs):
• Low Mass side: ≤5 x 10 -7
• High Mass side: ≤1 x 10 -7

 

Orthogonal detector system (ODS)

 

The ODS delivers higher sensitivity, lower background, and a wider linear dynamic range – up to 10 orders of magnitude from 0.1 cps to 4 Gcps. The detector life time is approximately twice as long as the 7700 detector.

 

Vacuum System

 

Three-stage differential vacuum system using a single, split-flow turbo molecular pump and single
external rotary pump for fast pump-down and simple maintenance.

 

Software Agilent ICP-MS MassHunter

 

 